Specifications
Quantity | Value |
---|---|
Physical | |
Size (HxWxD): | 37x42x16 mm / 1.46×1.65×0.63 inch |
Weight: |
|
Screw terminals max torque: | 0.4 Nm / 3.5 lbin |
Conductor cross section: | 0.2 to 2.5 mm² / 24 to 14 AWG (solid, stranded, and bootlace ferrules) |
Conductor stripped length: | 6 to 7 mm / 0.24 to 0.28 in |
Mounting: | Wall console, electrical cabinet |
Shell material: | Plastic |
Shell colour: |
|
Connectors colour: | Black |
Environmental | |
Ambient working temperature: | -20 °C to 40 °C / -5 °F to 105 °F |
Humidity: | 30 % to 70 % RH |
Max. altitude: | 2000 m / 6562 ft |
Electrical | |
Power supply: | 110 – 240 V~ 50/60 Hz |
Power consumption: | < 1.2 W |
Neutral not needed: | Yes or No |
External protection: | 2 A, tripping characteristic B or C, 6 kA interrupting rating, Energy limiting class 3 |
Output circuits ratings | |
Max. switching voltage: | 240 V~ |
Max. switching current: | 2 A/240 V~ |
Sensors, metres | |
Voltmeter (AC): | 110-240 V~ 50/60 Hz |
Voltmeter accuracy: | ±2% |
Ammeter (AC): | 0 – 80A |
Ammeter accuracy: | ±2 % (2 – 50 A), ±2 % (1 – 2 A), ±5 % (0 – 1 A) |
Compatible current transformers: |
|
Power and energy meters: |
|
Channel-to-channel calibration minimum load: | 500 W |
No load threshold: | 30 VA per channel |
Measurement data storage: | At least 10 days of 1 min data resolution |
Data export: |
|
Internal-temperature sensor: | Yes |
Radio | |
Wi-Fi | |
Protocol: | 802.11 b/g/n |
RF band: | 2412 – 2472 ?Hz |
Max. RF power: | < 20 dBm |
Range: | Up to 30 m / 100 ft indoors and 50 m / 160 ft outdoors (Depends on local conditions) |
Bluetooth | |
Protocol: | 4.2 |
RF band: | 2402 – 2480 MHz |
Max. RF power: | < 4 dBm |
Range: | Up to 10 m / 33 ft indoors and 30 m / 100 ft outdoors (Depends on local conditions) |
Microcontroller unit | |
CPU: | ESP-Shelly-C38F |
Flash: | 8 MB |
Firmware capabilities | |
Schedules: | Yes |
Webhooks (URL actions): | 20 with 5 URLs per hook |
Scripting: | Yes |
MQTT: | Yes |
Encryption: | Yes (Transport level) |
Authentication: | Yes (Application and transport level) |